Return to search results
💡 Advanced Search Tip
Search by organization or tag to find related datasets
University of Illinois Campus Deep Direct-Use Feasibility Study - Preliminary Geothermal Reservoir Model
Preliminary geothermal reservoir simulations were performed using a homogeneous static model to evaluate and understand the effects of fluid and rock properties that could influence the delivery of thermal energy in a doublet system. A 5000 feet by 5100 feet by 500 feet homogeneous model having a constant porosity and permeability of 20% and 100 mD was used to perform preliminary geothermal reservoir simulations. The model was discretized in the x-, y-, and z-directions into 100, 101, and 100, gridblocks. Two wells were placed on the opposite ends of the central column of the discretized model. One of the wells was designated as a producer and the other an injector.
Equal volumes of water was extracted and then injected into the reservoir via the production and injection wells. Water was extracted at a temperature of 109 deg F and re-injected at 50 deg F at the 1000 bbl/day.
The files attached contains the input and output files of this simulation case. The input and some of the output files can be viewed in any text editor.
Complete Metadata
| bureauCode |
[ "019:20" ] |
|---|---|
| dataQuality | true |
| DOI | 10.15121/1458562 |
| identifier | https://data.openei.org/submissions/7219 |
| issued | 2018-05-08T06:00:00Z |
| landingPage | https://gdr.openei.org/submissions/1065 |
| programCode |
[ "019:006" ] |
| projectLead | Arlene Anderson |
| projectNumber | EE0008106 |
| projectTitle | Geothermal Heat Recovery Complex: Large-scale, Deep Direct-Use System in a Low-Temperature Sedimentary Basin |
| spatial | {"type":"Polygon","coordinates":[[[-88.277125,40.011774],[-88.141987,40.011774],[-88.141987,40.112045],[-88.277125,40.112045],[-88.277125,40.011774]]]} |