Measurement of the Behavior of Steel Beams under Localized Fire Exposure

Published by National Institute of Standards and Technology | National Institute of Standards and Technology | Metadata Last Checked: June 27, 2025 | Last Modified: 2017-08-14 00:00:00
A total of nine localized fire tests on steel beams were designed and conducted in the National Fire Research Laboratory as part of its commissioning project, including thermal tests (Tests 1 through 5) and four-point bending test at ambient (Test 6) and elevated temperatures (Tests 7 through 9). All the tested specimens were nominally 6.2-m long W16×26 beams made of ASTM A992 steel. Each specimen was supported by one of the two following connections: (i) simple support (Tests 1 through 8), and (ii) double-angles bolted to laterally braced support columns (Test 9). The midspan of each specimen was exposed to an open-flame fire using the 1-m2 natural gas burners. The burner was located 1.1 m below the bottom flange of the beam at midspan. A four-point flexural loading scheme was used to apply concentrated forces at two locations 2.44 m apart around midspan. The data included temperatures, the heat release rates from the burner, and structural measurements including forces, displacements and strains. The Type B standard uncertainties in various measurements were also included. Overall, the test results showed that the heating rate of the specimen was sensitive to the prescribed heat release rate-time relationship. However, the thermal gradient developed in the fire-exposed cross sections of the beam never achieved linearity under the localized fire exposure. Regardless of the connection types and fire conditions (i.e., steady-state or transient-state fire), the beams exhibited a similar behavior and failure mode. When subjected to combined fire and flexural loads, the beam specimens exhibited the lateral-torsional buckling followed by runaway vertical displacements at midspan. Additional details of experimental procedures and uncertainty analysis for this experimental series are provided in the following publications: 1) Zhang, C., Choe, L., Gross, J., Ramesh, S., Bundy, M. (2017). Engineering Approach for Designing a Thermal Test of Real-scale Steel Beam Exposed to Localized Fire. Fire Technology, Vol 53, Issue 4, pp 1535-1554. DOI: 10.1007/s10694-016-0646-7 2) Choe, L., Ramesh, S., Zhang, C., Gross, J. (2016). The Performance of Structural Steel Beams Subjected to a Localized Fire. The 9th International Conference on Structures in Fire (SiF 16), June 8-10, 2016, Princeton, NJ.

Find Related Datasets

Click any tag below to search for similar datasets

Complete Metadata

data.gov

An official website of the GSA's Technology Transformation Services

Looking for U.S. government information and services?
Visit USA.gov